Electrical

FMI 3Voltage above normal or shorted to high source

The signal wire is seeing more voltage than the circuit should ever produce — usually the signal wire touching battery power or the 5 V reference.

Common causes

  • Signal wire shorted to a power or reference wire
  • Chafe at a bracket, clamp or through a frame pass-through
  • Water or coolant in the connector bridging pins
  • Failed sensor shorting internally

What to test, in order

  • Unplug the sensor and read the signal pin — a live reading with the sensor unplugged proves the short is in the harness
  • Check for battery voltage on the signal circuit key-on
  • Inspect the connector for moisture and corrosion, dry it and retest
  • Compare against a known-good sensor before replacing the harness